The DATA Klin series offers reliable and proven water-filtration solutions for data-center cooling towers, powered by Spin Klin™ NOVA disc technology, delivering continuous uptime, energy efficiency, long system life

No Downtime

Uninterrupted uptime with advanced particulate removal for critical cooling infrastructure

Corrosion Resistant

Ideal for corrosive data center cooling tower environments

Eco-Efficient

Minimizes water and energy consumption with scalable, sustainable design

Versatile

Covers cooling requirements from small data centers (0.5 MW) to campus-sized (500 MW) projects

Skid Models

3" Spin Klin™ Nova Single

Max. flow rate: 80 gpm Inlet/Outlet diameter: 4"/3"

4" Spin Klin™ Nova Plus Single

Max. flow rate: 240 gpm Inlet/Outlet diameter: 4"/3"

4" Spin Klin™ Nova Dual

Max. flow rate: 160 gpm Inlet/Outlet diameter: 5"/4"

6" Spin Klin™ Nova Plus Dual

Max. flow rate: 480 gpm Inlet/Outlet diameter: 5"/6"

6" Spin Klin™ Nova Plus Trio

Max. flow rate: 720 gpm Inlet/Outlet diameter: 6"/8"

Discover Our DATA Klin Solutions

Click Here

Amiad's patented

Spin Klin™ Disc Technology

Superior Filtration Efficiency

Consistent micron-level filtration for high-load, high-uptime cooling systems

Water-Saving Backwash

Efficient backwash conserves water while maintaining filtration performance

Longer Filtration Cycles

Higher dirt-holding capacity

Proven performance

Amiad uses the world recognized ISO 18471 as its standard test to verify its discs’ filtration degree, creating a direct correlation between filtration degree declaration and the filters’ actual performance.

Filtrate clogging ratio Spin Klin™ vs. other discs

FAQs

What problem does filtration solve in cooling towers?
Removes suspended solids and biological debris that cause fouling, scaling, and corrosion, preserving heat transfer efficiency and system reliability.

Is production interrupted during cleaning?
No. Cleaning cycles are triggered by differential pressure and occur online without disrupting flow.

Where is the filter installed?
Commonly on side-stream (5 - 10% of flow) or full-stream configurations based on system design.

How do I size a system?
Contact us. We will analyze flow, TSS/particle size, cycles of concentration, basin volume, and backwash water constraints to select the ideal system for you.

What maintenance is required?
Routine checks only - no cartridge changeouts. Backwash water is used as part of the blowdown process.

What’s the ROI?
Projects typically recoup investment through reduced energy, chemicals, and labor, and by avoiding unplanned outages. You can contact our filtration experts for a more detailed ROI estimate.